Compare commits
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
541ea43435 | ||
|
|
62d4641097 | ||
|
|
153d5d479f | ||
|
|
7ea6821116 | ||
|
|
b1747ef487 | ||
|
|
ff3434612b | ||
|
|
57bb21e5ba | ||
|
|
18b6d83af2 | ||
|
|
f097f7dabb | ||
|
|
55488681b2 |
@@ -46,5 +46,6 @@ STATE_ACTIVE = "active"
|
||||
STATE_OFF = "off"
|
||||
STATE_MANUAL_ON = "manual_on"
|
||||
STATE_MANUAL_OFF_COOLDOWN = "manual_off_cooldown"
|
||||
STATE_FORCE_STOPPED = "force_stopped"
|
||||
STATE_ERROR = "error"
|
||||
STATE_DISABLED = "disabled"
|
||||
@@ -28,6 +28,7 @@ from .const import (
|
||||
STATE_OFF,
|
||||
STATE_MANUAL_ON,
|
||||
STATE_MANUAL_OFF_COOLDOWN,
|
||||
STATE_FORCE_STOPPED,
|
||||
STATE_ERROR,
|
||||
STATE_DISABLED,
|
||||
)
|
||||
@@ -110,6 +111,9 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
attrs["main_sensors"] = self.main_sensors
|
||||
attrs["extend_sensors"] = self.extend_sensors
|
||||
attrs["lux_sensor"] = self.lux_sensor
|
||||
attrs["force_stop_sensor"] = self.force_stop_sensor
|
||||
attrs["force_stop_state"] = self.force_stop_state
|
||||
attrs["force_stop_active"] = self._state == STATE_FORCE_STOPPED
|
||||
attrs["active_main_sensors"] = self._get_active_main_sensors()
|
||||
attrs["active_extend_sensors"] = self._get_active_extend_sensors()
|
||||
attrs["lux_value"] = self._get_current_lux()
|
||||
@@ -154,8 +158,6 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
def set_manual_idle_timeout(self, value: float) -> None:
|
||||
self.manual_idle_timeout = int(value)
|
||||
self.logger.info("Manual idle timeout set to %d sec", self.manual_idle_timeout)
|
||||
|
||||
# Если таймер уже тикает, а мы изменили значение на 0, нужно его отменить
|
||||
if self.manual_idle_timeout <= 0 and self._manual_idle_timer:
|
||||
self.logger.info("Manual idle timeout set to 0, cancelling active timer")
|
||||
self._manual_idle_timer()
|
||||
@@ -175,6 +177,15 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
self.logger.info("Switches: %s, Main sensors: %s, Extend sensors: %s, Lux: %s",
|
||||
self.switch_entities, self.main_sensors, self.extend_sensors, self.lux_sensor)
|
||||
|
||||
# Проверяем состояние force_stop_sensor при старте
|
||||
if self.force_stop_sensor:
|
||||
force_stop_state_obj = self.hass.states.get(self.force_stop_sensor)
|
||||
if force_stop_state_obj and force_stop_state_obj.state == self.force_stop_state:
|
||||
self.logger.info("Force stop sensor is already in stop state at startup")
|
||||
await self._update_state(STATE_FORCE_STOPPED)
|
||||
await self._start_listening()
|
||||
return
|
||||
|
||||
any_on = any(
|
||||
self.hass.states.get(s) and self.hass.states.get(s).state == "on"
|
||||
for s in self.switch_entities
|
||||
@@ -294,6 +305,11 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
self.logger.debug("Integration disabled, ignoring")
|
||||
return
|
||||
|
||||
# БЛОКИРОВЩИК: Игнорируем движение, если активна принудительная остановка
|
||||
if self._state == STATE_FORCE_STOPPED:
|
||||
self.logger.debug("Ignoring during force_stopped")
|
||||
return
|
||||
|
||||
self.logger.debug("Main sensor ON by %s, current state: %s", triggered_by, self._state)
|
||||
|
||||
if self._state == STATE_MANUAL_OFF_COOLDOWN:
|
||||
@@ -302,7 +318,6 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
|
||||
if self._state == STATE_MANUAL_ON:
|
||||
self.logger.debug("During manual_on, resetting idle timer")
|
||||
# ИЗМЕНЕНИЕ: Сбрасываем таймер только если он включен (>0)
|
||||
if self.manual_idle_timeout > 0:
|
||||
self._reset_manual_idle_timer()
|
||||
return
|
||||
@@ -394,6 +409,11 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
self.logger.debug("Integration disabled, ignoring")
|
||||
return
|
||||
|
||||
# БЛОКИРОВЩИК: Игнорируем движение, если активна принудительная остановка
|
||||
if self._state == STATE_FORCE_STOPPED:
|
||||
self.logger.debug("Ignoring during force_stopped")
|
||||
return
|
||||
|
||||
self.logger.debug("Extend sensor ON by %s, current state: %s", triggered_by, self._state)
|
||||
|
||||
if self._state == STATE_IDLE:
|
||||
@@ -406,7 +426,6 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
|
||||
if self._state == STATE_MANUAL_ON:
|
||||
self.logger.debug("During manual_on, resetting idle timer")
|
||||
# ИЗМЕНЕНИЕ: Сбрасываем таймер только если он включен (>0)
|
||||
if self.manual_idle_timeout > 0:
|
||||
self._reset_manual_idle_timer()
|
||||
return
|
||||
@@ -440,6 +459,11 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
if not self.respect_manual:
|
||||
return
|
||||
|
||||
# БЛОКИРОВЩИК: Игнорируем ручные переключения, если активна принудительная остановка
|
||||
if self._state == STATE_FORCE_STOPPED:
|
||||
self.logger.debug("Ignoring manual change during force_stopped")
|
||||
return
|
||||
|
||||
new_state = event.data.get("new_state")
|
||||
old_state = event.data.get("old_state")
|
||||
if not new_state or not old_state:
|
||||
@@ -485,9 +509,27 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
if not new_state:
|
||||
return
|
||||
|
||||
# Если датчик перешел в блокирующее состояние
|
||||
if new_state.state == self.force_stop_state:
|
||||
self.logger.info("Force stop triggered by %s", event.data.get("entity_id"))
|
||||
self.hass.async_create_task(self._force_stop())
|
||||
self.hass.async_create_task(self._enter_force_stop())
|
||||
# Если датчик вышел из блокирующего состояния
|
||||
else:
|
||||
self.logger.info("Force stop released by %s", event.data.get("entity_id"))
|
||||
self.hass.async_create_task(self._exit_force_stop())
|
||||
|
||||
async def _enter_force_stop(self):
|
||||
"""Enter force_stopped state."""
|
||||
self.logger.info("Entering force_stopped state")
|
||||
self._cancel_all_timers()
|
||||
if self._state in (STATE_ON, STATE_DELAYING, STATE_ACTIVE, STATE_MANUAL_ON):
|
||||
await self._turn_off_switches()
|
||||
await self._update_state(STATE_FORCE_STOPPED)
|
||||
|
||||
async def _exit_force_stop(self):
|
||||
"""Exit force_stopped state to idle."""
|
||||
self.logger.info("Exiting force_stopped state")
|
||||
await self._update_state(STATE_IDLE)
|
||||
|
||||
def _is_any_main_sensor_active(self) -> bool:
|
||||
"""Check if any main sensor is currently in 'on' state."""
|
||||
@@ -658,11 +700,11 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
self.hass.async_create_task(self._update_state(STATE_IDLE))
|
||||
|
||||
async def _turn_on_switches(self) -> None:
|
||||
"""Turn on switches with our context."""
|
||||
"""Turn on switches/lights with our context."""
|
||||
ctx = Context(
|
||||
id=f"motion_light_{self.entry.entry_id}_{dt_util.utcnow().timestamp()}"
|
||||
)
|
||||
self.logger.info("Turning ON switches: %s", self.switch_entities)
|
||||
self.logger.info("Turning ON entities: %s", self.switch_entities)
|
||||
await self.hass.services.async_call(
|
||||
"homeassistant",
|
||||
"turn_on",
|
||||
@@ -671,11 +713,11 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
)
|
||||
|
||||
async def _turn_off_switches(self) -> None:
|
||||
"""Turn off switches with our context."""
|
||||
"""Turn off switches/lights with our context."""
|
||||
ctx = Context(
|
||||
id=f"motion_light_{self.entry.entry_id}_{dt_util.utcnow().timestamp()}"
|
||||
)
|
||||
self.logger.info("Turning OFF switches: %s", self.switch_entities)
|
||||
self.logger.info("Turning OFF entities: %s", self.switch_entities)
|
||||
await self.hass.services.async_call(
|
||||
"homeassistant",
|
||||
"turn_off",
|
||||
@@ -686,7 +728,6 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
async def _enter_manual_on(self):
|
||||
"""Enter manual_on state."""
|
||||
await self._update_state(STATE_MANUAL_ON)
|
||||
# ИЗМЕНЕНИЕ: Запускаем таймер только если он не отключен (не равен 0)
|
||||
if self.manual_idle_timeout > 0:
|
||||
self._reset_manual_idle_timer()
|
||||
else:
|
||||
@@ -694,7 +735,6 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
|
||||
def _reset_manual_idle_timer(self):
|
||||
"""Reset manual idle timer."""
|
||||
# ИЗМЕНЕНИЕ: Защита от создания таймера при значении 0
|
||||
if self.manual_idle_timeout <= 0:
|
||||
return
|
||||
|
||||
@@ -715,8 +755,8 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
self.hass.async_create_task(self._turn_off_switches_manual())
|
||||
|
||||
async def _turn_off_switches_manual(self):
|
||||
"""Turn off switches in manual mode."""
|
||||
self.logger.info("Turning OFF switches (manual timeout): %s", self.switch_entities)
|
||||
"""Turn off switches/lights in manual mode."""
|
||||
self.logger.info("Turning OFF entities (manual timeout): %s", self.switch_entities)
|
||||
await self.hass.services.async_call(
|
||||
"homeassistant",
|
||||
"turn_off",
|
||||
@@ -756,14 +796,6 @@ class MotionLightCoordinator(DataUpdateCoordinator):
|
||||
self._lux_cooldown_timer = None
|
||||
self.logger.info("Lux cooldown expired")
|
||||
|
||||
async def _force_stop(self):
|
||||
"""Force stop — turn off switches."""
|
||||
self.logger.info("Force stop called")
|
||||
self._cancel_all_timers()
|
||||
await self._turn_off_switches()
|
||||
await self._update_state(STATE_OFF)
|
||||
async_call_later(self.hass, 1, self._transition_to_idle)
|
||||
|
||||
def _cancel_all_timers(self):
|
||||
"""Cancel all timers."""
|
||||
if self._motion_detect_timer:
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
{
|
||||
"domain": "motion_light",
|
||||
"name": "Motion Light",
|
||||
"version": "1.0.0",
|
||||
"version": "1.0.2",
|
||||
"documentation": "https://github.com/sirmrak/motion_light",
|
||||
"issue_tracker": "https://github.com/sirmrak/motion_light/issues",
|
||||
"dependencies": [],
|
||||
|
||||
@@ -10,6 +10,7 @@ from homeassistant.helpers.restore_state import RestoreEntity
|
||||
from homeassistant.helpers.device_registry import DeviceInfo
|
||||
from .const import (
|
||||
DOMAIN,
|
||||
CONF_LUX_SENSOR,
|
||||
ENTITY_MOTION_FILTER,
|
||||
ENTITY_OFF_DELAY,
|
||||
ENTITY_LUX_THRESHOLD,
|
||||
@@ -70,16 +71,23 @@ async def async_setup_entry(
|
||||
) -> None:
|
||||
"""Set up Motion Light number entities."""
|
||||
coordinator = hass.data[DOMAIN][entry.entry_id]
|
||||
|
||||
lux_sensor = entry.options.get(CONF_LUX_SENSOR) or entry.data.get(CONF_LUX_SENSOR)
|
||||
|
||||
entities = [
|
||||
MotionLightNumber(coordinator, entry, ENTITY_MOTION_FILTER, 0, 10, 1, DEFAULT_MOTION_FILTER),
|
||||
MotionLightNumber(coordinator, entry, ENTITY_OFF_DELAY, 0, 600, 5, DEFAULT_OFF_DELAY),
|
||||
MotionLightNumber(coordinator, entry, ENTITY_LUX_THRESHOLD, 1, 1000, 10, DEFAULT_LUX_THRESHOLD),
|
||||
MotionLightNumber(coordinator, entry, ENTITY_LUX_COOLDOWN, 0, 300, 5, DEFAULT_LUX_COOLDOWN),
|
||||
MotionLightNumber(coordinator, entry, ENTITY_MANUAL_IDLE_TIMEOUT, 0, 3600, 60, DEFAULT_MANUAL_IDLE_TIMEOUT),
|
||||
MotionLightNumber(coordinator, entry, ENTITY_MANUAL_IDLE_TIMEOUT, 0, 3600, 30, DEFAULT_MANUAL_IDLE_TIMEOUT),
|
||||
MotionLightNumber(coordinator, entry, ENTITY_MANUAL_OFF_COOLDOWN, 0, 300, 5, DEFAULT_MANUAL_OFF_COOLDOWN),
|
||||
]
|
||||
async_add_entities(entities)
|
||||
|
||||
if lux_sensor:
|
||||
entities.extend([
|
||||
MotionLightNumber(coordinator, entry, ENTITY_LUX_THRESHOLD, 1, 1000, 10, DEFAULT_LUX_THRESHOLD),
|
||||
MotionLightNumber(coordinator, entry, ENTITY_LUX_COOLDOWN, 0, 300, 5, DEFAULT_LUX_COOLDOWN),
|
||||
])
|
||||
|
||||
async_add_entities(entities)
|
||||
|
||||
class MotionLightNumber(CoordinatorEntity, NumberEntity, RestoreEntity):
|
||||
"""Representation of a Motion Light setting as a number entity."""
|
||||
|
||||
@@ -45,6 +45,7 @@ class MotionLightStatusSensor(CoordinatorEntity, SensorEntity):
|
||||
"off": "mdi:lightbulb-off-outline",
|
||||
"manual_on": "mdi:hand-back-left",
|
||||
"manual_off_cooldown": "mdi:timer-pause",
|
||||
"force_stopped": "mdi:stop-circle-outline",
|
||||
"error": "mdi:alert-circle",
|
||||
"disabled": "mdi:lightbulb-off",
|
||||
}
|
||||
|
||||
@@ -55,6 +55,7 @@
|
||||
"off": "Off",
|
||||
"manual_on": "Manual on",
|
||||
"manual_off_cooldown": "Manual off cooldown",
|
||||
"force_stopped": "Force stopped",
|
||||
"error": "Error",
|
||||
"disabled": "Disabled"
|
||||
}
|
||||
|
||||
@@ -55,6 +55,7 @@
|
||||
"off": "Выключено",
|
||||
"manual_on": "Ручное включение",
|
||||
"manual_off_cooldown": "Пауза после ручного выкл.",
|
||||
"force_stopped": "Принудительная остановка",
|
||||
"error": "Ошибка",
|
||||
"disabled": "Отключено"
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user